1 removing the pallet, 6 positioning 3.6.1 warnings for positioning, English – CEMB USA ER85 Installation Manual User Manual

Page 8

Advertising
background image

ENGLISH

Installation manual Rev. 03-2012

8

3.5.1 Removing the pallet

The machine is secured to a base pallet. Prepare an adequate area with level flooring and mark it off before lifting
the machine and positioning it on the ground.

To remove the machine from the pallet operate as follows:

Remove the screws that lock the machine to the pallet


(figure on the side)

WARNING

MANUAL

HANDLING

AND

LIFTING

OF

THE

MACHINE

MUST

BE

CARRIED

OUT

WITH

THE

AID

OF

A

LIFT

TRUCK

.

PRISE

ON

THE

BASE

NEAR

THE

3

SUPPORT

POINTS

AS

SHOWN

IN

THE

FIGURE

BELOW

. O

THER

POINTS

,

SUCH

AS

THE

HEAD

OR

THE

ACCESSORY

TRAY

,

MUST

NOT

BE

FORCED

UNDER

ANY

CIRCUMSTANCES

.

3.6 POSITIONING

3.6.1 Warnings for positioning

The machine must be positioned respecting the following conditions:

Unpacking and positioning

The humidity and the temperature must be within the prescribed limits

(see paragraph 4.2).
The fire-fighting measures must be respected

Allow for sufficient space at the front, side and rear of the machine for

service or periodic maintenance and at the same time to assure

adequate air circulation. It is advisable to leave a space of about 1

metre around the machine.

The place where the machine is installed must be free of corrosive/

explosive powders or gas.

The place of installation must be vibration-free.

The lighting must be such that the various machine functions can clearly

be seen.
Lift the machine and position it correctly in its final position

(figure on

the side)

The machine must stand on a flat rigid surface and possibly away from

any joint in the floor.

INFORMATION

According to UNI EN 10380 regulations, the lighting for a generic working area (such as control rooms, fixed work-
stations in production plants, etc.) must on average be 300 lux (acceptable values between 200 and 500 lux). If
the machine is installed in a country different from Italy, the specific regulations in that country must be followed.

The lighting system must be such as to guarantee average lighting of 300 lux for the working environment. This value
depends on various factors, such as the characteristics of the working environment (more or less reflecting walls and
ceiling, height of the light points, etc.) and the type of bulbs used.

Advertising