CEMB USA C75SE (B) User Manual
Page 15
![background image](/manuals/326200/15/background.png)
I 0292 - 14
I 0292 - 15
GB
GB
5.3.2 - MANUAL PRESETTING
If necessary, the dimensions can be inserted or edited in manual mode as follows:
- press
+
or else press
from the Dimensions in automatic mode
screen (which can be reached by pulling out the distance + diameter gauge).
- press
to select the dimension to be preset (red).
- press
/
to preset the required value.
- press
to change unit of measurement.
- press
to preset the dimensions for the ALU-S correction mode
Definition of dimensions for correction using spring weights:
d = DIAMETER:
Preset the nominal diameter stamped on the rim.
b = WIDTH:
Preset the nominal width indicated on the rim.
a = DISTANCE:
Preset the distance of the inside of the wheel from the machine, after measuring
it with relative gauge as described in fig. 8.
In the event of correction type other than standard (spring weight), follow the instructions on the screen
for correct detection of dimensions.
Fig. 10a