4 - CONTROLS AND COMPONENTS

4.1 - BRAKE PEDAL

Fig. 5

This pedal allows the operator to hold the

wheel when fitting the counterweights.

It must not be actuated during the

measuring cycle.

4.2 - PNEUMATIC LOCKING PEDAL (Version SE)

Fig. 6

This pedal allows releasing the device

fastening the wheel on the adapter.

Do not actuate this pedal during the

machine cycle and/or when adapters

other than the standard cone adapter

are mounted.

The pedal has two stable positions:

top, wheel unclamped; bottom,

wheel clamped.

4.3 - AUTOMATIC DISTANCE AND DIAMETER GAUGE

This gauge allows measurement of the distance of the wheel from the machine and the wheel diameter

at the point of application of the counterweight. It also allows correct positioning of the counterweights on

the inside rim by using the specific function (see

Indication of exact correction weight position

) which

allows reading, on the monitor, the position used for the measurement within the rim (For calibration,

see the corresponding section).

The gauge can only be used with the counterweight pincers mounted.

4.4 - AUTOMATIC WIDTH GAUGE (OPTIONAL)

Width gauging is through a SONAR device which measures the distance of the wheel without mechanical

contact, merely by closing the guard and each time a valid measurement has been made with gauge

AUTOMATIC DISTANCE AND DIAMETER GAUGE

.

4.5 - AUTOMATIC WHEEL POSITIONING

At the end of the spin, the wheel is positioned according to the unbalance on the outside or else according

to the static unbalance (when selected).

Accuracy is ± 20 degrees.

4.6 - CLOCK CONTROL

The wheel balancer is provided with a clock having a back-up of about one month with the machine

switched off. If the machine remains off for a long period, at the first switch on, check the date and time

(see Clock set-up), adjusting them if necessary.