3 - recalculation of the unbalance, 4 - result of measurement – CEMB USA K10 (D) User Manual

Page 10

Advertising
background image

I 0215 - 10

GB

5.3 - RECALCULATION OF THE UNBALANCE

Press

after new setting of the measurement.

5.4 - RESULT OF MEASUREMENT

Fig. 7

Correction of inner side

Correction of outer side

After performing a balancing spin, the amounts of unbalance are shown on the digital readouts.

Digital readouts with LED ‘s 3 - 4 lit up indicate the correct angular wheel position to mount the counterwei-

ghts (12 o’clock position). If the audible alarm is enabled (see

FUNCTION MENU MANAGEMENT

) the acquisition

of the correction position is confirmed by a “beep” alarm.

In the event of unbalance less than the selected threshold value , is displayed in place of the unbalance

value , with

it is possible to read the values below the selected threshold gr. by gr.

NOTE: In the event of wheels with diameter less than or equal to 13” and at temperature conditions near

0°, the wheel balancer automatically engages a special measuring cycle involving two successive

measurements. The precision of unbalance values and the reliability of the wheel balancer are

unaffected. This type of operation is reset every time the wheel balancer is started.

If at the end of any balancing run, the flashing symbol

appears, manually turn the wheel

until unbalances are displayed.

Advertising