8 - routine maintenance, 9 - recommended spare parts list, For references, see exploded drawings) – CEMB USA K10 (D) User Manual

Page 17: 1 - to replace the fuses

Advertising
background image

I 0215 - 17

GB

8 - ROUTINE MAINTENANCE

Switch off the machine from the mains before carrying out any operation.

8.1 - TO REPLACE THE FUSES

Remove the weight holder shelf to gain access to the power supply board where the fuses are located

(see exploded drawings) . If fuses require replacement, use ones of the same current rating.

If the fault persists, contact Technical Service.

NONE OF THE OTHER MACHINE PARTS REQUIRE MAINTENANCE.

9 - RECOMMENDED SPARE PARTS LIST

(For references, see exploded drawings)

CODE

DESCRIPTION

020600503

Bearing 6005 - 2Z Ø 25/47/12

181198630

Spring 19863P

080077004

Rigid belt Poly V - TB2 - 770 - 4 crested

67M38954H

Position pick-up board with cable

05PR36154

LEXAN Panel

181206560

Distance gauge spring

67M36950A

Power board

681002000

Fuses DM5x20 - 2A

511242101

Bipolar platform switch (oscillating)

86SC40721

Computer board

SPECIAL PARTS FOR 230 V MACHINE

50FG54366

Single phase motor 230V/50-60 Hz - 0.12Kw HB63B-4

86SZ46810

Complete power board

611000314

Braking transformer 30 VA 230 - 0/50

568001058

Capacitor 10MF 450V Faston screw M8

611000308

Power transformer 30 VA 230 - 9/9

SPECIAL PARTS FOR 115V MACHINE

50FG54283

Single phase motor 115V/50-60 Hz - 0.12Kw HB63B-4

86SZ46811

Complete power board

611000313

Braking transformer 30 VA 0/115 - 0/30

568003558

Capacitor 35MF 450V FASTON screw M8

611000307

Power transformer 30 VA 115 - 9/9

SPECIFIC SPARE PARTS - CSA STANDARDS

50FG42403

Single phase motor BIMA 56/B14Kw0.11-4p CSA 115V/50-60Hz

67M36950C

Power board ( CSA )

681002001

Fuses DM5x20 - 2A type GMA ( CSA )

568003540

Electrical capacitor 35MF 250V MLR25U CSA M8 screw

611000301

Power supply transformer ( CSA )

611000310

Braking transformer ( CSA )

Advertising