6.2 - SELF-CALIBRATION

For machine self-calibration proceed as follows :

- Fit a wheel with steel rim of average dimensions on the shaft. Example 6” x 14” (± 1”)

- Preset the exact dimensions of the wheel mounted.

CAUTION !! Presetting of incorrect dimensions would mean that the machine is not correctly calibrated,

therefore all subsequent measurements will be incorrect until a new self-calibration is

performed with the correct dimensions!!

- Perform a spin under normal conditions.

- Add 100 g. (3.5 oz) on the outside in any angular position.

- Shift the 100 g.weight from the outside to the inside keeping the same

angular position.

- Rotate the wheel so to have the 100 g. weight to the 12 o’clock position.

END OF SELF-CALIBRATION

CANCEL SELF-CALIBRATION IN ANY PHASE