GB

5.4.1 - SPLIT FUNCTION (unbalance spread)

The SPLIT function is used to position the adhesive weights behind the wheel spokes so that they are

no longer visible. It is advisable to use this function only in the event of static unbalance or in the

ALU S function. Input the wheel dimensions and start the spin. To start the SPLIT function, input the

following data:

Display example prior to

SPLIT function

Input the number of spokes ( 3 ÷ 12 )

- Move any spoke to the 12 o’clock position

- Place the first Split unbalance in correction position 1

- Correction position 1

- Place the second Split unbalance in correction position 2

- Correction position 2

To return to normal unbalance display, press the button

To perform a new spin, subsequently press the button