Prosilica GX Technical Manual V2.0.8

37

Camera dimensions

Optical flange focal distance

Optical flange focal distance is the optical distance from the mounting flange to
the image sensor die (see figure 24 and figure 25). Optical flange focal distance
can be calculated as:

C-Mount cross section

Table 11 presents flange focal distance and maximum lens protrusion values for
Prosilica GX cameras with C-Mount.

Figure 24: Cross section of typical Prosilica GX front assembly with C-Mount

Camera Lens protrusion [mm] IR cut filter* [mm] Sensor window [mm]

Nominal flange focal

distance [mm]

GX1050

13.64

0.00

0.79

17.79

GX1050C

8.49

1.00

0.76

18.11

GX1660

13.64

0.00

0.76

17.78

GX1660C

8.49

1.00

0.76

18.11

GX1910

13.64

0.00

0.76

17.78

GX1910C

8.49

1.00

0.76

18.11

GX1920

13.64

0.00

0.75

17.78

GX1920C

3.84

1.00

0.75

18.11

GX2300

13.64

0.00

0.76

17.78

Table 11: Flange focal distance and maximum lens protrusion for Prosilica GX cameras with C-Mount