47

Camera interfaces

Lens control port

The lens control connector is a Hirose 3260-8S3. This connector provides the
signals necessary to control the iris, focus, and zoom of most commercially
available TV Zoom and Video-type auto-iris lenses. The cable side connector is
Hirose 3240-8P. The camera can be configured to operate lenses with unipolar
voltage requirements of 6–12 V or lenses that operate with bipolar voltages
from ±6 V up to ±12 V. This voltage level can be controlled through software. The
default voltage is set to 6 V. The current capacity for each axis is 50 mA.

Pin

Signal

Direction Description

1

Iris +

Out

Open Iris

2

Iris -

Out

Close iris

3

Focus +

Out

Focus far

4

Focus -

Out

Focus close

5

Zoom +

Out

Zoom out

6

Zoom -

Out

Zoom in

7

Video Iris

Out

PWM Signal for Iris Control

8

External GND ---

External Ground for all lens control signals

Table 16: Prosilica GX lens connector definition

Caution

Do not exceed the lens manufacturers voltage specification.

Note

This cable side Hirose connector can be purchased from AVT.