Camera interfaces

Input triggers

In 1 and In 2

In 1 and In 2 allow the camera to be synchronized to some external event. These
signals are optically isolated and require the signal common (Isolated IO GND).
The camera can be programmed to trigger on the rising or falling edge of these
signals. The camera can also be programmed to capture an image at some pro-
grammable delay time after the trigger event. These signals can be driven from
5 V to 24 V with a minimum current source of 5 mA.

Output signals

Output signals can be configured to active high or active low. The internal cam-
era signals are listed as follows:

Figure 29: Prosilica GX input trigger. Camera internal circuit

Note

Avago HCPL-063L are optically coupled gates that combine a
GaAsP light emitting diode and an integrated high gain photo
detector. These are used for the opto-isolated camera inputs.

Exposing

Corresponds to when camera is integrating light

Trigger Ready

Indicates when the camera will accept a trigger signal

Trigger Input

A relay of the trigger input signal used to “daisy chain” the
trigger signal for multiple cameras

Readout

Valid when camera is reading out data

Imaging

Valid when camera is exposing or reading out

Strobe

Programmable pulse based on one of the above events

GPO

User programmable binary output

180 R

1/10 W

TO CAMERA LOGIC

IN 2

ISOLATED IO GND

D

S

G

VCC

GND

HCPL-063L

1

2

3

4

7

6

8

5

VDD+3.3

IN 1

D

S

G

180 R

1/10 W

CAMERA INTERNAL EXTERNAL

Advertising