Prosilica GX Technical Manual V2.0.8

49

Camera interfaces

Motorized lens connection

Figure 32: Prosilica GX motorized lens connection diagram

Caution

WARNING

Verify lens voltage setting on camera does not exceed lens
voltage specification. Camera lens voltage is controlled by
software. This is set to 6 V after power up and cannot be saved
to user configuration files. Current capacity per axis = 50 mA.

FOCUS+

ZOOM

IRIS-

FOCUS

-

COMMON

FOCUS-

FOCUS

ZOOM-

ZOOM+

COMMON

ZOOM+

FOCUS

ZOOM

FOCUS+

COMMON

HIROSE 3240-8P-C(50)

1

2

3

4

5

6

7

8

TV ZOOM LENS

UNIPOLAR TYPE

ZOOM-

IRIS

IRIS

HIROSE 3240-8P-C(50)

1

2

3

4

5

6

7

8

IRIS-

COMMON

COMMON

COMMON

COMMON

IRIS+

IRIS+

TV ZOOM LENS

BIPOLAR TYPE