Prosilica GX Technical Manual V2.0.8

46

Camera interfaces

Out (1 to 4)

These signals are optically isolated and require the user to provide a high volt-
age level (Isolated Out Power) and signal common (Isolated IO GND). Iso-
lated Out Power
can be from 5 V to 24 V. An example of the functional circuit is
indicated in the diagram below.

Various Isolated Out Power values and load values for the above circuit are
indicated in the following table. Trigger current, OUT ICC, is a function of Iso-
lated Out Power
voltage and load resistor R.

Figure 30: Prosilica GX output trigger circuit

Note

Toshiba TLP281-4GB consist of photo transistor, optically cou-
pled to a GaAsP light emitting diode and an integrated high
gain photo detector. These are used for the opto-isolated cam-
era outputs.

ISOLATED
OUT POWER

OUT

ICC

R

V LOAD

R POWER

DISSIPATION

T

1

T

2

T

3

T

4

5 V

8 mA

500 Ω

4.1 V

32 mW

1.5 μs

6.5 μs

2 μs

14 μs

5 V

4.8 mA

1 KΩ

4.8 V

23 mW

1.5 μs

5 μs

17 μs

40 μs

12 V

9.2 mA

1.2 KΩ

11.2 V

101 mW

1.5 μs

11.2 μs

2 μs

20 μs

12 V

4.9 mA

2.4 KΩ

11.8 V

58 mW

1.5 μs

8.5 μs

17 μs

55 μs

24 V

9.5 mA

2.4 KΩ

23.2 V

217 mW

1.5 μs

22 μs

2 μs

37 μs

24 V

5 mA

4.8 KΩ

23.8 V

120 mW

1.5 μs

12 μs

17 μs

105 μs

Table 15: Prosilica GX trigger circuit values

T

4

T

2

T

3

CAMERA LOGIC SIGNAL

OUT

T

1

100K

442R

ISOLATED OUT POWER

R

ISOLATED IO GND

EXTERNAL

CAMERA INTERNAL

1

2

16

15

3.3 V CAMERA

LOGIC SIGNAL

OUT(1 to 4)

TLP281-4GB

Advertising