PHYSICAL

Dimensions:

W 482 x D 330 x H 45 mm

19”W x 13”D x 1.8”H.

(Compatible with a Standard 19” rack, Height = 1U).

Weight:

4.3 kg / 9.5 lbs.

ENVIRONMENTAL

Cooling air flow from right side to left side

Maximum ambient operating temperature: < 40°C ( < 104°F)

Operating temperature: 0 to +40°C / +32° to +104°F

Storage temperature: -40 to +70°C / -40° to +158 °F

Operating humidity: 10 to 80% (non condensing)

Input voltage range: 100-240 VAC, 50/60 Hz

Typical consumption: 90 W

CERTIFICATIONS

CE Compliancy test following

- EN 55022: 2006 / A1: 2007,

- EN 55024: 1998 / A1: 2001 / A2: 2003,

- EN 61000-3-2: 2006

- EN 61000-3-3: 1995 / A1: 2001 / A2: 2005,

Safety test following:

- IEC 60950-1: 2005

- UL 60950-1: 2007

- CAN/CSA-C22.2 NO. 60950-1

Power supply: IEC/EN/UL/CSA 60950-1, internal, autoswitchable

Mechanical (in carton): Vibration: IEC60068-2-64

Free fall: IEC60068-2-32, RoHS, WEEE

Environmental specifications

15

• COMMUNICATION PORTS:

REMOTE RS232

Connector:

DB 9 female

Level:

RS232.

Data Rate:

9600 Bauds, 8 data bits, 1 stop bit, no parity bit,

no flow control for normal. DTR & RTS needed for

upgrade.

Communication specifications

• LAN:

Connector :

RJ45

Protocol:

TCP (Transmission Control Protocol) or UDP

(User Datagram Protocol).

Ethernet:

Base 10/100