Datamax-O'Neil Class Series II Programmer’s Manual User Manual
Page 158

Label Formatting Command Functions
144
Class Series 2 Programmer’s Manual
Sample 2:
Assume printer date is set to January 01, 2013
<STX>L
tD0005
121100001000100 Expiration Date:<STX>D GHI PQ,
RSTU<STX> <<<<
E
Prints: Expiration Date:JAN 06, 2013 <<<<
STX S
Recall Global Data and Place in Field
This command, when in the format record data field, places data from a specified global
register into the data field. See the G command.
Syntax:
<STX>Sn
Where:
n
- Specifies the global register (A P) that contains the
data to place into the data field.
Sample:
<STX>L<CR>
121100000000000DMX<CR>
G<CR>
1A2210001000000<STX>SA<CR>
E<CR>
The sample above places the string “DMX” into the next available
global register (A), and then line 4 is effectively replaced by the
data from global register A.
STX T
Print Time and Date
This command, using string characters and markers, allows time and date data to be
selected and retrieved from the internal clock. In addition, the <STX>T may be preceded
by data to be printed/encoded, and/or the string may be terminated by an <STX>
command followed by more data then <CR> terminated. The string characters/markers
are not printed; instead, the label will show the corresponding print value.
Syntax:
<STX>Tstring<CR>
Where:
string
- Is any set of characters, A - Z and a – h; see the
table below.