Extended System-Level Command Functions





66

Class Series 2 Programmer’s Manual

(EP) End of Print – This command defines the signal output used to signify the End
of Print (EOP) process:

Value

Units

End of Print Interpretation

1 Low

Pulse

Outputs a low pulse (approximately 30 milliseconds long)

following printing.

2 High

Pulse

Outputs a high pulse (approximately 30 milliseconds long)

following printing.

3

Active Low

Outputs a logic low (zero) following printing.

4

Active High

Outputs a logic high (one) following printing.


(EQ) Start of Print – This command defines the type of signal input required to
control the Start of Print (SOP) process:

Value

Units

Start of Print Interpretation

3 Active

Low

SOP signal must go low for at least 50 milliseconds to initiate

printing.

4 Active

High

SOP signal must go high for at least 50 milliseconds to
initiate printing.



(ES) ESC Sequences – This command allows data containing invalid ESC control
code sequences to be processed (helpful because some systems send a “banner” to

the printer). When set to “Disabled,” ESC sequences are ignored and the data is
processed. Bitmapped font downloads are disabled in this mode.



(EV) Empty Sensor Level
–
This command sets threshold value for the “Empty”
media sensor parameter.



(FA) Format Attribute –
See the “An” command for details (Label Formatting

Command Functions).



(FB) Scalable Font Bolding –
This command sets a bolding factor to fine tune

scalable fonts, where one causes the least amount of bolding and thirty-six the most
(default value is 8).