Datamax-O'Neil Class Series II Programmer’s Manual User Manual

Page 20

Advertising
background image

Overview

6

Class Series 2 Programmer’s Manual

Configuration

Command

Name

Function

<STX>Kf

Set Present Distance

Determines label stop position, head
relative. <STX>f edge sensor relative
equivalent command, older models.

<STX>Kc

Configuration Set

Determines default power-up

configuration.

<STX>F

Send Form Feed

Sets the stop position of the printed

label.

<STX>M

Set Maximum Label Length

Length to search for next gap or

reflective mark; not used with

continuous media.

<STX>m

Set to Metric Mode

Subsequent measurements interpreted
in metric (most units, mm/10). Label

equivalent command can be used.

<STX>n

Set to Inch Mode

Subsequent measurements interpreted

in inches (most units in/100) label
equivalent command can be used.

<STX>O

Set Start of Print Position

Effect is not on the label immediately

following command since media position
is at Start of Print between labels;
<STX>K

default position relative 64

in/100 maximum deviation.

<STX>S

Set Feed Rate

Sets blank label movement speed.

<STX>V

Software Switch

Enables optional hardware, cutter, and

present sensor.

Advertising