Installation shutdown, Antifreeze protection, 4 installation shutdown – DE DIETRICH MODULENS AGC 15, AGC 25, AGC 35 User Manual

Page 25: 5 antifreeze protection

Advertising
background image

User level - Menu #TIME PROGRAM

Day

Comfort periods / Filling enabled:
P1
_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROG.DHW

Monday

Tuesday

Wednesday

Thursday

Friday

Saturday

Sunday

TIME PROG.AUX

Monday

Tuesday

Wednesday

Thursday

Friday

Saturday

Sunday

4.4

Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance. If the

central heating system is not used for a long period, we

recommend activating the HOLIDAYS mode (to ensure

the anti-grip of the heating pump).

4.5

Antifreeze protection

When the heating water temperature in the boiler is too low, the

integrated boiler protection system starts up. This protection functions

as follows:

4

If the water temperature is lower than 7°C, the heating pump starts

up.

4

If the water temperature is lower than 4°C, the boiler starts up.

4

If the water temperature is higher than 10°C, the boiler shuts down

and the circulation pump continues to run for a short time.

4

If the water temperature in the storage tank is less than 4°C, it is

reheated to its set point.

AGC 10/15 AGC 15 AGC 25 AGC 35

4. Operating the appliance

03/12/2013 - 300026080-001-03

24