Technical specifications

Boiler type

AGC 10/15 AGC 15

AGC 25

AGC 35

General
Nominal output (Pn)

Heating System (80/60 °C)

minimum-

maximum

kW

3,0 - 10,1

3,0 - 14,5

5,0 - 24,1

6,3 - 34,0

Nominal output (Pn)

Heating System (50/30 °C)

minimum-

maximum

kW

3,4 - 11,2

3,4 - 15,8

5,6 - 25,5

7,0 - 35,9

Nominal output (Pn)

Heating System (40/30 °C)

minimum-

maximum

kW

3,4 - 16,0

3,4 - 16,0

5,6 - 25,9

7,0 - 36.4

Nominal input (Qn)

Heating System (Hi)

minimum-

maximum

kW

3,1 - 10,5

3,1 - 15,0

5,2 - 25,0

6,5 - 35,1

Nominal input(Qn)

Heating System (Hs)

minimum-

maximum

kW

3,4 - 11,7

3,4 - 16,7

5,8 - 27,8

7,2 - 39,0

Nominal input (Qnw)

DHW System (Hi)

minimum-

maximum

kW

3,1 - 15,0

3,1 - 15,0

5,2 - 29,3

6,5 - 35,1

Nominal input (Qnw)

DHW System (Hs)

minimum-

maximum

kW

3,4 - 16,7

3,4 - 16,7

5,8 - 32,6

7,2 - 39,0

Heating efficiency under full load (Hi)

(80/60 °C)

-

%

96,5

96,5

96,3

96,9

Heating efficiency under full load (Hi)

(50/30 °C)

-

%

105,3

105,3

102,0

102,2

Heating efficiency under partial load

(Hi) (Return temperature 60°C)

-

%

94,9

94,9

96,1

96,3

Heating efficiency under partial load

(EN 92/42) (Return temperature

30°C)

-

%

108,8

108,5

108,0

108,2

Data on the gases and combustion gases
Gas consumption - Natural gas H

(G20)

minimum-

maximum

m

3

/h

0,33 - 1,59 0,33 - 1,59 0,55 - 3,10 0,69 - 3,71

Gas consumption - Natural gas L

(G25)

minimum-

maximum

m

3

/h

0,38 - 1,85 0,38 - 1,85 0,64 - 3,61 0,80 - 4,32

Gas consumption - Propane G31

minimum-

maximum

m

3

/h

0,13 - 0,61 0,13 - 0,61 0,21 - 1,20 0,27 - 1,44

NOx-Emission (Scrolls forward
EN297A3)

mg/kWh

33

33

38

41

Mass flue gas flow rate

minimum-

maximum

kg/h

5,3 - 25,2

5,3 - 25,2

8,9 - 49,3

11,1 - 57,3

Flue gas temperature

minimum-

maximum

°C

30 - 65

30 - 65

30 - 80

30 - 75

Maximum counter pressure

Pa

22

80

120

140

Characteristics of the heating circuit
Water content (ex expansion vessel)

l

1,9

1,9

1,9

2,5

Water operating pressure

minimum

kPa (bar (MPa)) 80 (0,8)

80 (0,8)

80 (0,8)

80 (0,8)

Water operating pressure (PMS)

maximum

kPa (bar (MPa)) 300 (3,0)

300 (3,0)

300 (3,0)

300 (3,0)

Water temperature

maximum

°C

110

110

110

110

Operating temperature

maximum

°C

90

90

90

90

Electrical characteristics

AGC 10/15 AGC 15 AGC 25 AGC 35

7. Technical specifications

03/12/2013 - 300026080-001-03