3. Press the ? key. Follow the instructions displayed to solve the

problem.

4. Consult the meaning of the codes in the table below:

Code Faults

Cause
of the
fault

Description

Checking / solution

L00

PSU FAIL

PCU

PSU PCB not connected

Bad connection

PSU PCB faulty

4

Contact the professional who takes care of

maintenance of the appliance

L01

PSU PARAM FAIL

PCU

The safety parameters are incorrect Bad connection

PSU PCB faulty

4

Contact the professional who takes care of

maintenance of the appliance

L02

DEF.OUTLET S.

PCU

The boiler flow sensor has short-

circuited

Bad connection

Sensor fault

4

Contact the professional who takes care of

maintenance of the appliance

L03

DEF.OUTLET S.

PCU

The boiler flow sensor is on an open

circuit

Bad connection

Sensor fault

4

Contact the professional who takes care of

maintenance of the appliance

L04

DEF.OUTLET S.

PCU

Boiler temp too low

Bad connection

Sensor fault

4

Contact the professional who takes care of

maintenance of the appliance

No water circulation

4

Vent the air in the heating system

4

Check the circulation (direction, pump,

valves)

4

Check the water pressure

L05

STB OUTLET

PCU

Boiler temperature too high

Bad connection

Sensor fault

4

Contact the professional who takes care of

maintenance of the appliance

No water circulation

4

Vent the air in the heating system

4

Check the circulation (direction, pump,

valves)

4

Check the water pressure

L06

BACK S.FAILURE

PCU

The return temperature sensor has

short-circuited

Bad connection

Sensor fault

4

Contact the professional who takes care of

maintenance of the appliance

bar

1

1

2

2

D

STD

J

I

E

0

2

4

6

8

10

12

14

16

18

22

24

20

#

F

AUTO

% $

<

:



!

SUNDAY 11:45

TEMP. : 68°

PCU COM.FAIL D27