CAUTION
4
The antifreeze protection does not function if the
appliance is switched off.
4
The integrated protection system only protects the
boiler, not the installation. To protect the installation,
set the appliance to HOLIDAYS mode.
The HOLIDAYS mode protects:
4
The installation if the outside temperature is lower than 3°C
(factory setting).
4
The room temperature if a remote control is connected and the
room temperature is lower than 6 °C (factory setting).
4
The domestic hot water tank if the tank temperature is lower
than 4 °C (the water is reheated to 10 °C).
To configure the holidays mode: ¼See chapter: "Selecting the