Code

Messages

Description

Checking / solution

B27

BL.DHW INST

The sensor on the plate

exchanger outlet is disconnected

or short circuited

4

Contact the professional who takes care of

maintenance of the appliance

B28

BL.BAD.CONFIG

An HL tank is detected whilst the

boiler cannot control it.

This message disappears after

10 seconds if the boiler can

control the HL tank

4

Wait for 10 seconds to see whether the error persists

4

Contact the professional who takes care of

maintenance of the appliance

B29

to

B34

BL.UNKNOWN Bxx

Incorrect configuration of the

PCU

4

Contact the professional who takes care of

maintenance of the appliance

M04

REVISION

A service is required

The date programmed for the service has been reached

4

If the symbol ? flashes, press key ?. The installer’s

contact details are displayed.

4

Contact the professional who takes care of

maintenance of the appliance

M05

REVISION A

An A, B or C service is required The date programmed for the service has been reached

4

If the symbol ? flashes, press key ?. The installer’s

contact details are displayed.

4

Contact the professional who takes care of

maintenance of the appliance

M06

REVISION B

M07

REVISION C

M20

DISGAS

A boiler vent cycle is underway Switching the boiler on

4

Wait 3 minutes

FL.DRY.B XX DAYS

Floor drying is active
XX

DAYS = Number of days’

floor drying remaining.

Floor drying is underway. Heating on the circuits not

concerned is shut down.

4

Contact the professional who takes care of

maintenance of the appliance

FL.DRY.C XX DAYS
FL.DRY.B+C XX
DAYS

M23

CHANGE OUTSI.S

The outside temperature sensor

is defective.

Change the outside radio temperature sensor.

6.3

Faults (Code type Lxx or Dxx)

In the event of operational failure, the control panel flashes and

displays an error message and a corresponding code.
1. Make a note of the code displayed.

The code is important for the correct and rapid diagnosis of the

type of failure and for any technical assistance that may be

needed.

2. Press the t key. If the code is displayed again, switch off the boiler

and then switch it back on.

bar

1

1

2

2

D

STD

J

E

0

2

4

6

8

10

12

14

16

18

22

24

20

#

F

AUTO

% $

<

:



!

SUNDAY 11:45

TEMP. : 68°

PCU. COM. FAIL. D27