Model 5861e – Brooks Instrument 5861E User Manual

Page 11

Advertising
background image

2-3

Model 5861E

Section 2 Installation

Installation and Operation Manual

X-TMF-5861E-MFM-eng
Part Number: 541B107AAG
November, 2008

PIN NO.

FUNCTION

COLOR CODE

1

Cmd. Common (Command Pot "CCW")

Black

2

0-5 Volt Signal Output

White

3

Supply Common

Red

4

Valve Off

Green

5

+15 Vdc Supply

Orange

6

-15 Vdc Supply

Blue

7

Valve Test Point/Purge

Wht/Blk

8

Cmd. Input or Cmd. Pot "S"

Red/Blk

9

Supply Voltage Common

Grn/Blk

10

0-5 Volt Signal Common

Org/Blk

11

+5 Volt Reference Output (Command Pot "CW")

Blu/Blk

12

Valve Override

Blk/Wht

13

Not Used

Red/Wht

14

Chassis Ground

Grn/Wht

15

Remote Transducer Input* •

Blu/Wht

* Factory Activated Option.

These connections are used for the 5850E and 5851E Mass Flow Controllers.

Make no connections to these pins.

NOTE:

1. Cable shield tied to chassis ground
in meter connector. Make no
connection on customer end.

2. All power leads must be connected
to power supply.

Figure 2-1 Model 5861E Dimensions

Figure 2-2 "D" Type Connector Pin Arrangement

Advertising