General technical data – Burkert Type 0789 User Manual

Page 11

Advertising
background image

11

Technicaldata/Safeoperation

6.3.5. Type of explosion protection

The composition of the explosion protection code follows the explosion
protection types of the components used in each case:

Solenoid with or without
terminal box

II 2 G Ex d e IIC T4 resp. T5
II 2 D Ex tD A21 IP 65 T135 °C resp.
T100 °C

Solenoid with terminal
box and fuse

II 2 G Ex d e mb IIC T4
II 2 D Ex tD A21 IP65 T135 °C

Solenoid without terminal
box with proximity switch

II 2 G Ex d e ia IIC T4 resp. T5
II 2 D Ex tD A21 IP65 T135 °C resp.
T100 °C

Solenoid with terminal
box, fuse and proximity
switch

II 2 G Ex d e ia mb IIC T4
II 2 D Ex tD A21 IP65 T135 °C

6.4. general Technical data

6.4.1. electrical data

Type

77. - ... - ... - .

78. - ... - ... - .

Temperature class

T4

T5

Type of current

Universal

Universal

rated voltage

24 ... 240 V

24 ... 240 V

Voltage tolerance

+10 % / -10 %

+10 % / -10 %

rated current

0,085 ... 0,014 A

0,085 ... 0,014 A

pick-up current

01,66 ... 0,166 A

01,66 ... 0,166 A

pick-up power

40 W

40 W

power consumption for
holding in equilibrium

3 W

3W

max. number of
switching actuations ca

20 / min

10 / min

6.4.2. electrical connection

Version

code

execution

internal

code

PD30*

* Permanently installed rubber sheathed
cable of Type H05 RN-F3G0.75

****JWxx

english

PTB 03 ATEX 1030 X