Special instructions in explosion-risk areas, General safety instructions – Burkert Type 0789 User Manual

Page 6

Advertising
background image

6

GeneralSafetyInstructions

2.3. special instructions in explosion-risk

areas

WarnInG!

danger caused by electrostatic charge!
If there is a sudden discharge from electrostatically charged devices
or persons, there is a danger of explosion in the explosion-risk area.
• Take appropriate measures to prevent electrostatic charges in

explosion-risk areas.

• Clean the device surface by gently wiping it with a damp or

antistatic cloth only.

Additional special conditions can be found under “5.1” of
these operating instructions.

3. general safeTy insTrucTiOns

These safety instructions do not take into account
• any contingencies or events which may occur during the installation,

operation and maintenance of the devices.

• local safety regulations, the observance of which is the responsibility

of the operator, also with respect to the installation personnel.

danger of explosion!
• The device is a sealed system. It must not be opened
danger of electrostatic charge!
Acute risk of injury from hazardous structure-borne voltage!
Risk of damage to the device due to short circuit!
• Before starting work, switch off the power supply and secure to

prevent it being switched on again!

• Observe the applicable accident prevention and safety regula-

tions for electrical devices!

danger - high pressure!
• There is a serious risk of injury when reaching into the

equipment.

• Before loosening the lines and valves, turn off the pressure and

vent the lines.

• Observe the currently valid accident prevention and safety

regulations!

english

PTB 03 ATEX 1030 X