Disassembly, Start-up, Safety instructions – Burkert Type 0789 User Manual

Page 14

Advertising
background image

14

Start-up

The connection cable is encapsulated with the coil and
cannot be removed.

Attach the electrical connection.

7.4. disassembly

DanGEr!

risk of electric shock!
There is a serious risk of injury when reaching into the equipment.
• Only trained electrical engineers may work on the electrical

system.

• Before starting work, always switch off the power supply and

safeguard to prevent re-activation!

• Observe applicable accident prevention and safety regulations

for electrical equipment!

procedure:

Disconnect the power connection.

Disconnect the valve body from the pipeline.

notE!

malfunctions as a result of contamination!
• In case of new installation, remove old PTFE tape from the connec-

tions. Residues or parts of the tape must not get into the pipeline.

8. sTarT-up

8.1. safety instructions

WarnInG!

danger due to improper operation!
Improper operation may result in injuries as well as damage to the
device and the area around it.
• Before start-up, ensure that the operating personnel are familiar

with and completely understand the contents of the operating

instructions.

• In particular observe the safety instructions and intended use.
• The device may be started by adequately trained personnel only.

before commissioning, ensure that:
• The device has been correctly installed,
• The connections have been correctly made,
• The device is not damaged,
• All bolts are securely tightened.

english

PTB 03 ATEX 1030 X

Advertising