Assemblyanddisassembly

DanGEr!

danger of high voltage!
Acute risk of injury from hazardous structure-borne voltage!
Risk of damage to the device due to short circuit!
• Before starting work, switch off the power supply and secure to

prevent it being switched on again!

• Live terminals in the terminal box can cause electric shock, short

circuit or explosion. Switch off the power supply before open-

ing the terminal box.

• The connecting cables to the electromagnets must be secure,

and be laid so that they are adequately protected from mechani-

cal damage.

• Observe the applicable accident prevention and safety regula-

tions for electrical devices!

WarnInG!

danger - high pressure!
Interventions in the pneumatic system represent an acute risk of
injury.
• First switch off pressure before disconnecting lines and valves.
• Observe the flow direction during installation.
• Observe the applicable accident prevention and safety regula-

tions for pneumatic systems.

7.2. installation of valve

The solenoid valve can be mounted in any position.
Preferably with solenoid system mounted at the top.

procedure:

→

Clean pipelines.

→

Connect a dirt trap upstream.

→

Seal pipeline connections with PTFE tape.

→

Screws in pipelines.

Make certain the direction of flow is correct!

→

Check valve for leakage.

7.3. electrical connection

DanGEr!

risk of injury due to electrical shock!
• Before reaching into the system, switch off the electrical power

supply and secure to prevent reactivation!

• Observe applicable accident prevention and safety regulations

for electrical equipment!

if the protective conductor contact between coil and body is
missing, there is danger of electrical shock!
• Always connect protective conductor.
• Check electrical continuity between coil and body.

english

PTB 03 ATEX 1030 X