Burkert Type 8041 User Manual

Page 51

Advertising
background image

49

Maintenanceandtroubleshooting

10.4. replacing the seal on a device

with G2" nut

note

Do not scratch the seal groove.

1

2

3

Seal

Groove

Fig. 47: Dismounting the device and location of the seal

→

Loosen the nut of the device (mark 2).

→

Remove the device from the fitting (mark 1).

→

Remove the seal from the groove.

→

Clean the seal groove.

→

Insert the new O-ring in the groove (see chap. 11).

→

Insert the device into the fitting.

→

Tighten the nut (mark 2) by hand on the device.

10.5. if you encounter problems

danger

risk of injury due to high pressure in the installation.
• Stop the circulation of fluid and cut off the pressure before

loosening the process connections.

risk of injury due to electrical voltage.
• Shut down the electrical power source of all the conductors and

isolate it before carrying out work on the system.

• Observe all applicable accident protection and safety regula-

tions for electrical equipment.

risk of injury due to high fluid temperatures.
• Use safety gloves to handle the device.
• Stop the circulation of fluid and drain the pipe before loosening

the process connections.

risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident prevention and

safety relating to the use of aggressive fluids.

English

Type 8041

Advertising