Alliance Laundry Systems Extractors P232156R9 User Manual

Page 10

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Basic Installation/Operation

F232156

8

Table 1 (continued)

Specifications

35

60

80

100

125

150

Direct Steam Heating (Optional)

Steam inlet connection size,
in (mm)

0.5 (13)

0.5 (13)

0.5 (13)

0.5 (13)

0.75 (19)

0.75 (19)

Number of steam inlets

1

1

1

1

1

1

Steam required to
raise bath temperature
10°F, lb (10°C, kg)

LOW

2.1 (1.5)

3.3 (2.4)

4.6 (3.3)

5.7 (4.1)

6.7 (4.9)

8.3 (6.0)

MED

2.3 (1.7)

3.7 (2.6)

5.2 (3.8)

6.5 (4.7)

7.8 (5.6)

9.5 (6.9)

HIGH

2.7 (1.9)

4.1 (2.9)

6.1 (4.4)

7.6 (5.5)

9.1 (6.6)

11.1 (8.0)

Average consumption per
cycle, BHP (kg)

1.4 (21.4)

2.1 (33.4)

3.1 (48.4)

3.8 (60.4)

4.6 (72.0)

5.8 (91.0)

Electrical Heating (Optional)

Total electrical heating
capacity, kW (N/A for 2-speed
models)

15.6

27.4

41.2 (Q-Volt)
27.4 (N-Volt)

41.2 (Q-Volt)
27.4 (N-Volt)

N/A

N/A

Number of electrical heating
elements

6

6

9

9

N/A

N/A

Electrical heating element size,
kW

2.6

4.2

4.2

4.2

N/A

N/A

Time required to
raise bath temperature
10°F, min (5°C, min)

LOW

2.4 (3.6)

2.4 (3.7)

2.2 (3.4)

2.8 (4.2)

N/A

N/A

MED

2.7 (4.1)

2.7 (4.1)

2.5 (3.9)

3.2 (4.8)

N/A

N/A

HIGH

3.1 (4.7)

3.0 (4.6)

3.0 (4.5)

3.7 (5.6)

N/A

N/A

Table 1

Advertising