Alliance Laundry Systems Extractors P232156R9 User Manual

Page 14

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Basic Installation/Operation

F232156

12

Table 3 (continued)

UWPV Models

Specifications

35

60

80

100

125

150

Cylinder Speeds / Centrifugal Force Data

1/2 Wash/reverse, RPM / g

26 / .25

26 / .31

26 / .35

26 / .35

26 / .40

23 / .31

Wash/reverse, RPM / g

42 / .66

40 / .73

40 / .82

40 / .82

37 / .82

36 / 0.8

Distribution, RPM / g

83 / 2.57

71 / 2.29

73 / 2.57

70 / 2.50

62 / 2.29

61 / 2.29

Medium extract, RPM / g

325 / 39

305 / 42

325 / 54

325 / 54

260 / 40

262 / 42

High extract l, RPM / g
*Design U6 models

474 / 84

435 / 86

408 / 85

408 / 85

380 / 86

417 / 106

533 / 106

483 / 106

456 / 106

456 / 106

N/A

417 / 106

High extract 2, RPM / g

610 / 139

555 / 140

523 / 140

523 / 140

485 / 140

512 / 160

High extract 3, RPM / g
*Design U6 models

795 / 235

720 / 235

671 / 230

601 / 184

534 / 170

573 / 200

897 / 308

813 / 300

767 / 300

767 / 300

580 / 200

701 / 300

Balance Detection

Vibration switch installed

STD

STD

STD

STD

STD

STD

Switch gap setting, in. (mm)**

.20 (.008) NO-GO

.15 (.006) GO

.25 (.010) NO-GO

.20 (.008) GO

.25 (.010) NO-GO

.20 (.008) GO

.25 (.010) NO-GO

.20 (.008) GO

.20 (.008) NO-GO

.15 (.006) GO

.30 (.014) NO-GO

.33 (.013) GO

Direct Steam Heating (Optional)

Steam inlet connection size,
in. (mm)

1/2 (13)

1/2 (13)

1/2 (13)

1/2 (13)

3/4 (19)

3/4 (19)

Number of steam inlets

1

1

1

1

1

1

Steam required to
raise bath temperature,
10°F, lb. (10°C, kg)

LOW

2.1 (1.5)

3.3 (2.4)

4.6 (3.3)

5.7 (4.1)

6.7 (4.9)

8.3 (6.0)

MED

2.3 (1.7)

3.7 (2.6)

5.2 (3.8)

6.5 (4.7)

7.8 (5.6)

9.5 (6.9)

HIGH

2.7 (1.9)

4.1 (2.9)

6.1 (4.4)

7.6 (5.5)

9.1 (6.6)

11.1 (8.0)

Average consumption per cycle,
bhp (kg)

1.4 (21.4)

2.1 (33.4)

3.1 (48.4)

3.8 (60.4)

4.6 (72.0)

5.8 (91.0)

Electrical Heating (Optional)

Total electrical heating capacity,
kW

15.6

25.2

37.8

37.8

50.4

N/A

Number of electrical heating
elements

6

6

9

9

12

N/A

Electrical heating element size,
kW

2.6

4.2

4.2

4.2

4.2

N/A

Time required to
raise bath temperature,
10°F, min. (5°C, min.)

LOW

2.4 (3.6)

2.4 (3.7)

2.2 (3.4)

2.8 (4.2)

2.5 (3.8)

N/A

MED

2.7 (4.1)

2.7 (4.1)

2.5 (3.9)

3.2 (4.8)

2.9 (4.4)

N/A

HIGH

3.1 (4.7)

3.0 (4.6)

3.0 (4.5)

3.7 (5.6)

3.4 (5.1)

N/A

*

Refer to Figure 4 and Figure 5, and serial number decal on machine to determine design series.

** Gap setting should be made with “GO–NO-GO” type feeler gauge.
N/A = Not Applicable

Table 3

Advertising