Regeneration Cycle Step Programming

This program step programs the Regeneration Cycle step times 1 through 5. Please refer to the chart below

for regenerant flow default cycle steps and times..

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

Media Volume

This program step sets the volume of the media in the resin tank..

— Press the Shift button to select the digit you want to modify..

— Press the Up or Down buttons to adjust this value..

— Press the Extra Cycle button.
Salt Dosage

This program step sets the salt dosage in the unit..

— Press the Shift button to select the digit you want to modify..

— Press the Up or Down buttons to adjust this value..

— Press the Extra Cycle button.
Brine Line Flow Control Size

This program step allows the selection of the desired brine line flow control size in the unit (must match

physical brine line flow control)..

— Press the Up or Down buttons to adjust this value..
— Press the Extra Cycle button.
Auxiliary Relay Output

The next two displays are part of a series of settings used to program the optional relay output. The first.

setting turns the output on/off during regeneration only. The second turns the output on during service only,

every time a set volume of water used has accumulated..

NOTE: When auxiliary outputs are in the OFF (default) setting, press the Up or Down buttons to set

the first setting. Then press the Extra Cycle button to advance to the second setting.

11.

12.

13.

14.

15.

Master Programming Mode

Regenerant Flow

Cycle 1

Time

Cycle 2

Time

Cycle 3

Time

Cycle 4

Time

Cycle 5

Time

Down Flow

Back Wash

10.

Minutes

Brine

& Slow

Rinse

1 Hour

Rapid

Rinse

10.

Minutes

Brine Tank Fill

12 Minutes

N/A

N/A

Back Wash Filter

Back Wash

15.

Minutes

Draw

0

Settling

Rinse

10.

Minutes

Refill

0

N/A

N/A

UF Back Wash

Backwash

10.

Minutes

Brine

& Slow

Rinse

1 Hour

Rapid

Rinse

10.

Minutes

Brine Tank Fill

12 Minutes

N/A

N/A

Down Flow Double

Backwash

Back Wash

10.

Minutes

Brine

& Slow

Rinse

1 Hour

Back

Wash

10.

Minutes

Rapid Rinse

10 Minutes

Brine Tank Fill

12 Minutes

Up Flow

Brine Rinse

60

Back

Wash

10

Rapid

Rinse

10.

Minutes

Brine Tank Fill

12 Minutes

N/A

N/A

Upflow Variable Fill

Brine Rinse

Variable

Pause

60.

minutes

Brine

Rinse

60.

Minutes

Back Wash

12 Minutes

Rapid Rise

10 Minutes