Master programming mode – Hydrotech 6700 XTR Valve Downflow Automatic Water Softeners Service Manual User Manual

Page 16

Advertising
background image

Page 16

a. Timed Auxiliary Relay Output Window (Start & End Time Setting)

This option setting consists of two displays. The first display sets the turn-on time of the output, referenced

to the start of the first regeneration cycle. The second display sets the output turn-off time, referenced again

to the start of the first regeneration cycle. An OFF setting cancels this setting. All settings are in minutes and

output timing is synchronized with regeneration cycle timing..

.

.

Start Time: Any time during regeneration..

.

End Time: At start time, and anytime during the regeneration cycle..

.

.

.

.

..

b. Chemical Pump Auxiliary Relay Output Window

This option setting consists of two displays. The first display sets the volume of water flow at which the output

turns on. The second display sets the on time (in seconds) of the output..

— Activate output after volume set is reached..

— Press the Shift button to select the digit you want to modify..

— Press the Up or Down buttons to adjust this value..

— Press the Extra Cycle button..

.

.

.

.

Flow Meter Size

This program step sets the size of the flow meter.

.

— Press the Up or Down buttons to adjust this value..

— Press the Extra Cycle button..

.

.

.

.

Maximum Flow Rate

This program step sets maximum flow rate of the generic flow meter..

— Press the Shift button to select the digit you want to modify..

— Press the Up or Down buttons to adjust this value..

— Press the Extra Cycle button.
Pulses per Gallon/Liter

This program step sets the pulses per gallon/liter for generic flow meters..

— Press the Shift button to select the digit you want to modify..

— Press the Up or Down buttons to adjust this value..

— Press the Extra Cycle button.
End of Master Programming Mode

16.

17.

18.

19.

CAUTION: Before entering Master Programming, please contact your local professional water dealer.

Master Programming Mode

Advertising