Timer Operation

Regeneration:

• A time initiated control valve regenerates when the number of programmed days has been reached

• A flow initiated control valve regenerates when the volume count is zero or is below reserve.

capacity

System Type

Regeneration Trigger

Time Clock Delayed

A) Day override parameter is reached and B) the time of day

matches the regeneration day override time

Meter Immediate

Regenerates as soon as the volume remaining has been

depleted

Meter Delayed Fixed Reserve

A) Volume remaining has been depleted to the fixed reserve

volume and B) the regeneration time has been reached

Meter Delayed Variable Reserve

A) Volume remaining has been depleted to the variable

reserve volume and B) the regeneration time has been

reached

Meter Delayed Weekly Reserve

A) Volume remaining has been depleted to the weekly

variable reserve volume and B) the regeneration time has

been reached

Volume Override Immediate

As soon as the programmed volume remaining has been

depleted from the tank

Volume Override Delayed

As soon as soon as the programmed volume remaining has

been depleted from the tank and the regeneration time has

been reached

Setting the Time of Day

Press and hold the Up or Down button for 2 seconds.

Press the Shift button to select the digit you want to modify.

Press the Up or Down buttons to adjust the value.

Press the Extra Cycle button to return to the normal display screen, or after a 5 second timeout.

NOTE: The “D” button (Diagnostic) can be pressed to exit without saving.

Manually Initiating a Regeneration

When timer is in service, press the Extra Cycle button for 5 seconds on the main screen.

The timer advances to Regeneration Cycle Step #1, and begins programmed time count down.

Press the Extra Cycle button once to advance valve to Regeneration Cycle Step #2 (if active).

Press the Extra Cycle button once to advance valve to Regeneration Cycle Step #3 (if active).

Press the Extra Cycle button once to advance valve to Regeneration Cycle Step # (if active).

Press the Extra Cycle button once to advance valve to Regeneration Cycle Step #5 (if active).

Press the Extra Cycle button once more to advance the valve back to in service.

NOTE: A queued regeneration can be initiated by pressing the Extra Cycle button. To clear a queued regenera-

tion, press the Extra Cycle button again to cancel. If regeneration occurs for any reason prior to the delayed

regeneration time, the manual regeneration request shall be cleared.

1.

2.

3.

4.

1.

2.

3.

4.

5.

6.

7.