2 - opening & closing the gates – CAME Krono-S5D Kit User Manual

Page 20

Advertising
background image

19

ON

OFF

1.

Momentarily pulse terminals 2 & 3 with a
piece of wire trailing from terminal 2 and
momentarily touching terminal 3.

The gates should start to open. If they start
to close turn the power off to the control
panel and change around either U-V (motor
1) or X-Y (motor 2) to change the motor
direcrion.

2.

Once you have proven the motor direction
use terminals 2 & 7 to open and close the
gates with a trailing wire once again into
terminal 2, momentarily touching terminal 7.

5.

Select dipswitches 1 & 2 OFF for
commissioning.

6.

Ensure hard wire link is fitted between
terminals 1 & 2 and 2 & C1.

L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1

L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1

L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1

3.2 - Opening & Closing the Gates

Fig 20

Fig 21

Fig 22

Fig 23

Advertising
This manual is related to the following products: