4 - automatic close & activating safety photocells – CAME Krono-S5D Kit User Manual

Page 22

Advertising
background image

21

3.4 - Automatic Close & Activating

Safety Photocells

1.

To select automatic closing, select dipswitch 2 ON.

Set the automatic closing time by adjusting potentiometer TCA.

Fully anti-clockwise will automatically close the gates after approximately 10 seconds and fully
clockwise will close the gates after approximately 80 seconds. A sensible setting is about halfway (ie
6 o’clock position) which will automatically close the gates after approximately 30 seconds.

2.

For re-opening during closing. Remove hard wire link
between 2 & C1 and insert safety beam wires as
shown.

10 11 1 2 3 5 7 C1

10 2 NC

ON

OFF

1

1

TRIMMER TCA

6 O’CLOCK POSITION

Fig 27

Fig 28

Fig 29