3.3 - Control Panel Adjustments

1.

To delay one gate leaf, adjust potentiometer TR2M to delay the closing of gate no.2 in the closing
cycle.

2.

To set the total running time of the motors, adjust potentiometer TL to allow the motors to run for
a further 5-7 seconds after the movement cycle has been completed (ie fully open or fully
closed).

3.

Check the sensitivity of the gates by trying to
physically stop the gate and adjust the power
settings on the transformer accordingly. If more
power is needed for heavier gates then switch off
power and move transformer wire up to setting 2.
For rechecking sensitivity, repeat process up to 3 or
4 if even more power is needed.