37

Appendix A Modbus register

Table 7 Sensor Modbus register

Tag name

Register #

Data type

Length

R/W

Description

SLUDGELEVEL m

40001

Float

2

R

Measured sludge level in m

SLUDGELEVEL ft

40003

Float

2

R

Measured sludge level in ft

SLUDGEHEIGHT m

40005

Float

2

R

Measured sludge height in m

SLUDGEHEIGHT ft

40007

Float

2

R

Measured sludge height in ft

PLUNGERDEPTH m

40009

Float

2

R/W

Plunger depth in m

PLUNGERDEPTH ft

40011

Float

2

R/W

Plunger depth in ft

BOTTOM m

40013

Float

2

R/W

Tank depth in m

BOTTOM ft

40015

Float

2

R/W

Tank depth in ft

SET PARAMETER

40017

Unsigned integer

1

R/W

Type of measurement: sludge level,
sludge height

MEAS UNITS

40018

Unsigned integer

1

R/W

Dimension set: meters, feet

FACTOR

40019

Float

2

R/W

Correction factor for the measured value:
0.9–1.1

WIPE

40021

Unsigned integer

1

R/W

Wiper status

ERROR

40022

String

8

R

Error shown

EDITED NAME

40022

String

8

R/W

Name of the measuring location

CLEAN. INTERVAL

40030

Unsigned integer

1

R/W

Wiper interval

RESPONSE TIME

40031

Unsigned integer

1

R/W

Response time: 10–600 seconds

FADE-OUT

40032

Unsigned integer

1

R/W

Blanking: ON/OFF

BEGIN m

40033

Float

2

R/W

Blanking start in m

BEGIN ft

40035

Float

2

R/W

Blanking start in ft

END m

40037

Float

2

R/W

Blanking end in m

END ft

40039

Float

2

R/W

Blanking end in ft

LOGGER INTERVAL

40041

Unsigned integer

1

R/W

Logger interval

THRESHOLD AUTO

40042

Unsigned integer

1

R/W

Automatic threshold function: ON/OFF

THRESHOLD

40043

Float

2

R/W

Threshold value (manual): 0.1–50

WINDOW

40045

Unsigned integer

1

R/W

Window

PROFILE COUNTER

40046

Unsigned integer

1

R/W

Wiper profile counter

SERIAL NUMBER

40047

String

6

R

Serial number

TEST / MAINT

40053

Time2

2

R/W

Date of the last maintenance

PROGRAM

40055

Float

2

R

Application version

BOOTPROG.

40057

Float

2

R

Boot loader version

STRUCTURE

40059

Unsigned integer

1

R

Structure driver version

FIRMWARE

40060

Unsigned integer

1

R

Firmware driver version

CONTENT

40061

Unsigned integer

1

R

Register driver version

FormatMinSL m

40062

Float

2

R

Lower sludge level limit in m

FormatMaxSL m

40064

Float

2

R

Upper sludge level limit in m

FormatMinSL ft

40066

Float

2

R

Lower sludge level limit in ft

FormatMaxSL ft

40068

Float

2

R

Upper sludge level limit in ft

FormatMinSH m

40070

Float

2

R

Lower sludge height limit in m

FormatMaxSH m

40072

Float

2

R

Upper sludge height limit in m

FormatMinSH ft

40074

Float

2

R

Lower sludge height limit in ft

FormatMaxSH ft

40076

Float

2

R

Upper sludge height limit in ft

MOIST

40078

Unsigned integer

1

R

Moisture signal

Advertising