Appendix: Accessory DOS Programs

160

68-11824-210

Running HIB Configure

Perform the following steps to program a HIB-232 module with the modem "AT" command string:

1.

Connect the HIB-232 module to the serial port specified above for the ctihib.sys driver in the
CONFIG.NT file.

2.

Ensure that

OPTION A

Switches 1 and 3 are UP, all others DOWN

OPTION B

switches

should all be DOWN. SER MODE switches should all be UP.

3.

Apply power to the HIB-232.

4.

Open a DOS window (click the

Start

button, select “Run…”, type “

command

” in the text

box, then click

OK

).

5.

In the DOS window, navigate to the MCNRCD directory for DOS Utilities with the following
command:

cd C:\Program Files\CTI Products Inc\McnRcd Standard\Dos

Utilities\Hib

6.

Type the following

hibcnfg /38400 usrspvi

then press the Enter key. “usrspvi” is the name of the file that contains the initialization string for a
generic V.34 US Robotics modem. If your modem is different, check with CTI Products to select
the most appropriate file.Placeholder for Section Header.