background image

MCNConfig Program: Receivers Resource Window

63

68-11824-210

Description

Free format text field for general customer use. Many customers use this field to store an
identifier for the leased line, microwave channel, or T1 channel bank and channel number for
this receiver. This field is not required for program operation. Can be used in error logging &
emails

You can also cut & paste descriptions from Excel. See Using the Clipboard from other
Applications
on Page 89 for more details.

Tag-1

This is a free-format user defined field. It is used with the TPCI option in the Advanced Server
software. You can use it as a note field in the Standard Server software.

Tag-2

This is a free-format user defined field. It is used with the TPCI option in the Advanced Server
software. You can use it as a note field in the Standard Server software.

Display Table

This is the mapping table to use for this receiver (or alarm point). The Display Table determines
how the input bits from the hardware modules are mapped to the status display.

If you have all receivers, you will probably just use the "Comparator" table. This maps the
inputs to the standard "Vote", "Rx", "Dis", and "Fail" statuses.

If you have some Input / Output groups that are used for things such as microwave or site
alarms, you will need to select a different Display Table (such as "Generator", "Door" or
"Power") for those points.

This is a drop-down field. Select one of the Display Tables from the drop-down list.