68-11824-210

Hardware Resource Window

This is a list of hardware modules in the system.

The Hardware Resource Window includes the following fields:

NI

Network Interface to use for this module.
This is a drop-down field that will let you select from the defined Network Interfaces for this
system (either PCLTA, HIB-232, or HIB-IP). In the example above, there is a HIB-IP at the
Communications Center connecting to the modules there and another at the Hilltop Water Tank.

Group

MCN Group Number for this module (Hex value 00-FE)

Module

MCN Module Number for this module (Hex value 0-F)

Type

Module Type from the following table:

Module Type Description

Receivers or I/O Blocks

CIB

Comparator Interface

8

AIB

Astrotac Comparator
Interface

8, 16, 24, 32, 40, 48, 56, 64
(Depending on Bank setting)

IOB Std
(4 bits each)

General I/O Controller

8 I/O Blocks

IOB 2 Bit
(2 bits each)

General I/O Controller

16 I/O Blocks

IOB 1 Bit
(1 bit each)

General Input Device

32 Input Blocks

Banks

Number of receiver banks (8 receivers per bank). AIB modules can have up to 8 banks. All
other modules have only 1 bank. A drop-down list is provided.

Location

Typically refers to site name for this particular module.

Free format text field for customer use.
Not required for program operation.
Can be used in error logging & emails

Name

Typically used to identify a particular module.

Free format text field for customer use.
Not required for program operation.
Used in error logging & emails.