Nstalling, Olenoid – Controlled Products Systems Group SLIDESMART DC 10F User Manual
Page 100

Installing a MagLock or Solenoid Lock
6-2
SlideSmart DC Installation and Reference Manual
Revision D
6. Mount an external antenna onto the top of a fixed fence post near the operator.
7. Connect the antenna into the socket on the radio receiver.
8. Set the “DIP” switches in the receiver to match the same code used in the transmitter.
NOTE
If an edge sensor transmitter is also used to reverse the gate, be certain to use a two channel
commercial receiver. The edge and hand held transmitters must have their codes set to match
the receiver or they will not function.
I
NSTALLING
A
M
AG
L
OCK
OR
S
OLENOID
L
OCK
To provide additional gate security, a maglock or a solenoid lock can be used and connected to the Smart DC
Controller. The Smart DC Controller releases the lock prior to initiating gate movement. Before installing the
lock, be sure to:
•
Determine the electrical power requirements of your lock (maglock or solenoid lock). Electronic board and
peripheral connections differ between high voltage and lower voltage gate operators.
•
Determine the current required. A total combined current draw of 1 amp is available from the 24VDC,
24VAC, or 12VDC power supply. If the peripherals attached to the terminals need more than 1 amp, a separate
power supply is required. Refer to