Aster, Lave, Iring – Controlled Products Systems Group SLIDESMART DC 10F User Manual
Page 96: Onnections

Master and Slave Wiring Connections
5-2
SlideSmart DC Installation and Reference Manual
Revision D
M
ASTER
AND
S
LAVE
W
IRING
C
ONNECTIONS
Figure 5-2.
1. As shown in Figure 5-2, connect a shielded communications cable to the DUAL GATE inputs in each
unit. The inputs are located near the base of the Smart DC Controller. Be sure to connect the wires in pairs
to the same terminal ports (A-A, B-B, and COM to COM) on both units. See Table 5-1.
2. Attach a ring terminal to the shield wire and connect it to the Smart DC Controller’s convenient ground
screw. Refer to Figure 5-2.
NOTE
Connect the ground shield wire to only one operator, not both.
Table 5-1.
Slave
Master
A
A
COM
COM
B
B
Shield wire to Ground*
* Only ground to one
unit. Do NOT attach the
shield wire to both units.
COM
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
RADIO OPTIONS
EDGE +24V OP
EN COM
DUAL GATE
B
A
U
SE
R2
COM NO
DC
USER 1
COM
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
RADIO OPTIONS
EDGE +24V OP
EN COM
DUAL GATE
B
A
U
SE
R2
COM NO
DC
USER 1
Master
Slave
Conduit (in the ground)
Shielded cable
(3-wire)
Shield wire
Note: Do not connect the ground shield
wire at both ends.
Ground