Figure 2-10 – Controlled Products Systems Group SLIDESMART DC 10F User Manual
Page 51

Important Considerations for DC-powered Operators
Revision D
Power
2-13
4. Place the two 50Ah batteries on
the tray.
5. Attach the blue wire from the
red terminal on one 50Ah
battery to the black terminal on
other 50Ah battery.
6. Run the red and black wires
(disconnected from the 8Ah
batteries) through the hole in
the support bracket.
7. Using the wires supplied in the
50Ah battery kit, attach the red
wire to the red positive terminal
on the 50Ah battery. Connect
its opposite end to the red lead
exiting the support bracket.
8. Connect the black wire to the
black negative terminal on the
50Ah battery. Connect its
opposite end to the black lead
exiting the support bracket.
9. Access the Installer Menu on the
Smart DC Controller.
10. Change the Battery Setting (BT)
in the Installer Menu to a
number 1 (Extended). Follow
the steps in the menu tree
shown here.
Black
Blue
Red
Figure 2-10.
50Ah batteries
Accessory tray
Post-mounted
operator with
base extension
BT 1 (EXTENDED)
BATTERY TYPE
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
1. Start at a gate status display.
2. Access the User Menu, by
pressing MENU twice.
3. Access the Installer Menu, by
simultaneously pressing OPEN
and RESET. Release the buttons.
4. Use NEXT to navigate to the
menu display. Change the setting
using the SELECT and NEXT
buttons.
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT