Front installation -14, Ront, Nstallation – Controlled Products Systems Group SLIDESMART DC 10F User Manual
Page 36

Gate Bracket and Chain Installation
1-14
SlideSmart Installation and Reference Manual
Revision D
8. To verify that the operator recognizes the target magnet, turn off both DC and AC power switches and
watch the display go blank. Then, turn both switches on. The operator beeps indicating Limit Relearn
Mode. The gate then travels about 6 inches (15cm) in the open direction and stops. The buzzer beeps
again and the gate travels in the close direction at a rate of ½ ft/s until the target magnet passes the target
sensor. The buzzer sounds one last time, the operator resets, and “GATE CLOSED” appears on the
display.
9. If “LEARN OPEN” appears, then the target magnet was not detected. Check chain alignment and make
sure the target magnet passes across the face of the sensor. See Figure 1-18. Repeat steps 6 - 8. If you are
still having difficulty with the operator learning its limits, re-install the target magnet. See
on page 1-12.
F
RONT
I
NSTALLATION
Figure 1-19.
CAUTION
When the gate is CLOSED, the target magnet should stop between the idler wheel and
the roller chain sprocket. The target magnet MUST NOT enter the sprocket teeth. See
Figure 1-19.
PUBLIC
PUBLIC
SECURE
SECURE
Roller chain sprocket
Idler wheel
Target
(LH gate)
sensor
Position of the target
magnet when the gate is
fully closed.
Second target
sensor is not used
Trailing edge of gate
(Gate shown in full
CLOSE position)