6 interfaces, 1 interface setup, 2 24v dc power supply – ADS-TEC VMT6008 User Manual

Page 23

Advertising
background image

VMT6008

22

© ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen

6 Interfaces 

6.1 Interface Setup 

 

Interface 

IRQ 

Adress 

COM1 

3F8h 

RFID (Touch) 

2F8h 

 

Pos: 26 /Datentechnik/Schnittstellen/Spannungsversorgung/Spannungsversorgung für VMT60xx-Serie @ 2\mod_1260450284020_6.doc @ 6853 @

6.2 24V DC Power Supply 

The supply voltage is provided via a lead‐through terminal including a screw connection (Phoenix Contact 
COMBICON MC 1,5/4‐STF3.81). (The figure shows the socket inside the device) 
 

Pin‐Number 

Signal‐Name 

 

PE 

0V DC 

Ignition contact 

24V DC 

 

Voltage tolerance 

•Input voltage: 24 V DC ± 20%. 

Current consumption 

The current consumption of this device depends on the equipment version  

(e.g. if a heater or WLAN, etc. is installed.) 

 

• 

Switch‐on current: 7A (1ms) 

• 

Standby current consumption: 0.25mA 

• 

Regular operation: 1.3A without heater  

(without any additional load on the USB ports and without delivering the +5V supply for the scanner) 

 

 

Note: 

The power supply can be protected with a slow‐blow fuse of up to 4A.

 

 

Note: 

The typical power consumption of this device is indicated in the "Technical details" 
chapter.

Advertising