Laurel Electronics Custom ASCII Protocol For Laureate Series 2 Digital Panel Meters, Counters, Timers & L-Series Transmitters User Manual
Page 32

32
32 (L)
Serial Cnfg2
Bit 7 6 5 4 3 2 1 0
X X X X X Binary Custom ASCII addr. 0-31
0
Continuous mode
1
Command mode
0
Alarm data not included with rdg.
1
Alarm data included with rdg.
0
No <LF> following <CR>
1
<LF> following <CR>
31 (L)
Serial Cnfg1
Bit 7 6 5 4 3 2 1 0 Continuous Output Data Rate
60 Hz
50 Hz
0 0 0 0
0.017s
0.02s
0 0 0 1
0.28
0.34
0 0 1 0
0.57
0.68
0 0 1 1
1.1
1.4
0 1 0 0
2.3
2.7
0 1 0 1
4.5
5.4
0 1 1 0
9.1
10.9
0 1 1 1
18.1
21.8
1 0 0 0
36.3
43.5
1 0 0 1
1:13
1:27
1 0 1 0
2:25
2:54
1 0 1 1
4:50
5:48
1 1 0 0
9:40
11:36
1 1 0 1
19:20
23:13
1 1 1 0
38:41
46:25
1 1 1 1
1:17:21 1:32:51
0 0 0
300 baud
0 0 1
600 baud
0 1 0
1200 baud
0 1 1
2400 baud
1 0 0
4800 baud
1 0 1
9600 baud
1 1 0
19200 baud
0
Send unfiltered value
1
Send filtered value