Laurel Electronics Custom ASCII Protocol For Laureate Series 2 Digital Panel Meters, Counters, Timers & L-Series Transmitters User Manual
Page 54

54
12.3 WEIGHT METER 3-BYTE RAM MEMORY DATA (3 Bytes / Item)
All numeric values except scale factor utilize a 2’s complement, 3-byte Hex format, where the
MS byte, Mid byte and LS byte each consist of two Hex nibbles: XX XX XX.
Polarity and decimal point for scale are set by the most significant Hex nibble of the most
significant byte (leftmost byte) as follows:
MS Bit
Polarity & Dec Pt
1
2
3
4
5
6
9
A
B
C
D
E
XXXXX.
XXXX.X
XXX.XX
XX.XXX
X.XXXX
.XXXXX
- XXXXX.
- XXXX.X
- XXX.XX
- XX.XXX
- X.XXXX
- .XXXXX
Hex addresses for numeric values are also in the 3-byte Hex format, as explained in 12.1,
as follows:
Numeric Value
MS Byte
Mid Byte
LS Byte
Analog high value
Analog low value
Setpoint 2 Diff
Setpoint 1 Diff
Offset value
Scale factor
Setpoint4
Setpoint3
Setpoint2
Setpoint1
Tare value
A1 (L)
9E (L)
9B (L)
98 (L)
8F (L)
8C (L)
15 (U)
12 (U)
89 (L)
86 (L)
E3 (L)
A0
9D
9A
97
8E
8B
14
11
88
85
E2
9F
9C
99
96
8D
8A
13
10
87
84
E1
12.4 WEIGHT METER NONVOLATILE MEMORY HEX ADDRESSES (2 Bytes / Address)
Please see the 1 Byte RAM Data Table for bit definitions.