Hv duo pro gun, Introduction – Magnum Venus Plastech High Duo Pro Gun User Manual

Page 13

Advertising
background image

MAGNUM VENUS PLASTECH HIGH VOLUME DUO PRO GUN

13




HV Duo Pro Gun

Introduction


Generally, the HV Dual Pro Gun™ will not need to be completely disassembled for
daily cleaning. However, the entire gun should be disassembled and the o-rings and
seals replaced approximately every six months depending on use.

Disassembling the HV Dual Pro Gun™ is easy; the gun breaks down into two separate
modules which are then disassembled further into their individual parts. A special tool
kit (HVPG-TOOLS), which includes a specially designed HV Pro Gun™ tool and a
packing assembly tool, is available to aid in performing maintenance and repair.

Tools required

• You will need the following tools:

• Rubber mallet
• Thread Sealant
• Adjustable wrench
• Needle-nose pliers
• Flat-end screwdriver
• Lubriplate™ lubricant (08465)
• Scribe set (08126)
• Pro Gun™ oil (04394)
• Seal Installation tool (58198-1)
• HV Pro Gun™ packing bit (58199-1)

• You should also have appropriate cleaning materials such as solvent, clean

shop towels or rags, a small brush, and empty containers into which you will
flush the gun.

• Also, you will need new o-rings and seals to replace the current ones in the HV

Duo Pro Gun™. Please refer to the parts drawings to obtain proper parts
numbers for the o-rings and seals to be replaced.


Note: If you are using o-ring part number O-K-008 in the flush assembly, you do
not need to replace the o-ring unless it is showing obvious signs of wear. This
o-ring is specially designed to handle most solvents
.

DANGER: To prevent accidental injection injury, disconnect all air and electrical
power to the unit before beginning repair or maintenance on this equipment.

CHAPTER

1

Advertising