Magnum Venus Plastech High Duo Pro Gun User Manual

Page 17

Advertising
background image

MAGNUM VENUS PLASTECH HIGH VOLUME DUO PRO GUN

17

Remove Gun Head / Mix Chamber


There are four (4) Gun Heads (mix chambers) available for the HV Duo gun:

• HVDG-2202

Gun Head – Pipe thread – 3/4” Mixer

• HVDG-2204

Gun Head – Recirculation – Ratio

• HVDG-2212

Gun Head – Disposable Mixer

• HVDG-2214

Gun Head – Standard HV Pro Gun Mix Chamber


1.

Remove any items connected to the front of the Gun Head – Nozzle, Mixer ….


2.

Remove the two Front plugs and Seals – use caution as the Spring and Ball
may fall out.

3.

Remove the Spring and Ball from the Gun Head (if applicable to assembly).

4.

Remove the Side Plugs and seals from the Gun Head.

5.

Remove the Gun Head by unscrewing the four (4) screws holding the Gun
Head to the gun block. Use caution not to drop the Locator Pin.

6.

Remove the two Check Face seals from the Gun Block.

7.

Inspect and clean the Gun Head and components with solvent.





FRONT PLUG

SWIVEL FITING

CAP SCREWS

SIDE PLUG

SPRING

BALL

FACE SEAL

GUN BLOCK

O-RING

SEAL

LOCATOR PIN

Advertising