FLUSH BODY

PUSH STEM

O-RING

BACK-UP RING

GRIP RING

SPRING

FLUSH VALVE BODY

HOSE CLAMP

BARBED FITTING

SEAL

9.

Install the spring and push stem into the flush body.

10. Install a new o-ring onto the end of the push stem sticking out of the flush body.

11. Install the back-up ring onto the end of the push stem against the new o-ring.

12. Install the grip ring onto the end of the push stem.

13. Thread the auto/manual flush body assembly into the flush valve body.

14. Screw the flush valve assembly (5104-01-01) into the front side port on the

resin side of the gun block


Note: If using o-ring part number O-K-008 (o-ring is used on the flush button),
you do not need to replace the o-ring unless it is showing obvious signs of
wear or damage. This o-ring is specially designed for use with all solvents.

Note: In some cases O-K-008 o-ring can be replaced with the more economical
o-ring (O-E-008).

Assemble Gun Head

1.

Install the two Check Face Seal into the front of the Gun block.


2.

Install the Locator Pin into either the Gun block or Gun head.

3.

Mount the Gun Head onto the Gun Block using the four Cap screws.


Note: the following procedure will apply to all configurations expect the Ratio
Gun head setup (HVDG-2204).

4.

Install the Side Plugs and Seals into both sides of the Gun Head.

5.

With the Gun head pointing upward place the Ball into the front port of the Gun Head.