Magnum Venus Plastech High Duo Pro Gun User Manual

Page 23

Advertising
background image

MAGNUM VENUS PLASTECH HIGH VOLUME DUO PRO GUN

23

Reinstall Hose Fittings

1.

Reinstall the Hose Fitting and o-ring for the resin and hardener hoses on the
rear of the Gun block.

Reassemble Flush Valve

FLUSH VALVE BODY -

AUTO/MANUAL

SPRING

SEAL

O-RING

O-RING

FLUSH SEAL BODY

FLUSH VALVE NECK

FLUSH VALVE BUTTON

SPLIT SEAL

FLUSH VALVE BODY

1.

Place the O-ring (O-E-008) on the Flush valve button (5104-25-1).

2.

Insert the Spring (9203-2-3) onto the Flush valve button.

3.

Place the O-ring (O-E-007) on the Flush seal body (5104-23-1).


4.

Push the Button and Spring into the Flush valve body (5104-24-1).

5.

Insert the Flush seal body (5104-23-1) into the end of the Flush valve body
and screw it onto the Button.

6.

Place a Flush valve seal (5104-26-1) on the Flush valve body.

7.

Install the Flush valve body (5104-24-1) into the Flush valve neck (5104-22-1).

8.

Install the Split seal (5104-21-1) onto the Flush valve body (5104-24-1).


Note: For systems without Auto/Manual flush assemblies skip steps 9 – 13

Advertising