Reinstall Hose Fittings
1.
Reinstall the Hose Fitting and o-ring for the resin and hardener hoses on the
rear of the Gun block.
Reassemble Flush Valve
FLUSH VALVE BODY -
AUTO/MANUAL
SPRING
SEAL
O-RING
O-RING
FLUSH SEAL BODY
FLUSH VALVE NECK
FLUSH VALVE BUTTON
SPLIT SEAL
FLUSH VALVE BODY
1.
Place the O-ring (O-E-008) on the Flush valve button (5104-25-1).
2.
Insert the Spring (9203-2-3) onto the Flush valve button.
3.
Place the O-ring (O-E-007) on the Flush seal body (5104-23-1).
4.
Push the Button and Spring into the Flush valve body (5104-24-1).
5.
Insert the Flush seal body (5104-23-1) into the end of the Flush valve body
and screw it onto the Button.
6.
Place a Flush valve seal (5104-26-1) on the Flush valve body.
7.
Install the Flush valve body (5104-24-1) into the Flush valve neck (5104-22-1).
8.
Install the Split seal (5104-21-1) onto the Flush valve body (5104-24-1).
Note: For systems without Auto/Manual flush assemblies skip steps 9 – 13